Quantitative Waveform Capnography Use in ACLS
Quantitative waveform capnography is used in ACLS to objectively assess good CPR;confirm placement of an endotracheal tube; identify return of spontaneous circulation; and during post-cardiac arrest care.We can use waveform capnography with, and without, an advanced airway in place.Monitoring end tidal CO2 during rescue breathing.Use of capnography to objectively measure good CPR.Capnography is a preferred method of confirming endotracheal tube (ETT) placement over x-ray during a code.During CPR, a sudden increase in ETCO2 may indicate ROSC.Quantitative waveform capnography use in the post-cardiac arrest algorithm.Good luck with your ACLS class!Links: Buy Me a Coffee at https://buymeacoffee.com/paultaylor Practice ECG rhythms at Dialed Medics - https://dialedmedics.com/Safe Meds VIP - Learn about medication safety and download a free drug discount card to save money on prescription medications for you and your pets: https://safemeds.vipPass ACLS Web Site - Episode archives & other ACLS-related podcasts: https://passacls.com@Pass-ACLS-Podcast on LinkedIn